Common Fault Alarm and Solution Of Fiber Laser Cutting Machine
| Alarm location |
Alarm name |
Alarm reason and inspection method |
|
Floating head alarm |
Body capacitance becomes smaller |
1. Nozzle is not installed |
|
2.The ceramic ring is loose |
||
|
3.Wiring problem |
||
|
Abnormally large capacitance |
Calibration problem, re-calibrate |
|
| Servo alarm | 1. Z axis servo is not turned on | |
|
2.There is a problem with the servo wiring, please check all servo plugs. |
||
| Z+ Limit valid |
Z+ limit trigger |
|
| Z- Limit valid |
Z- limit trigger |
|
| Communication time out |
1.The network cable is not connected |
|
|
2. Reset height controller IP |
||
|
3 Height controller is closed |
||
|
Servo alarm |
Alarm code: 910, 710, 720 |
1. Servo is not turned on |
|
2. There is a problem with the servo wiring, please check all servo plugs. |
||
| Limit alarm |
Y+ Limit |
Limit trigger |
|
Y-Limit |
Something hits the limit |
|
|
X+ Limit |
Replace the limit problem |
|
X- Limit |
The adapter board is faulty |
|
|
The cutting effect suddenly deteriorates |
1. No calibration after material replacement | |
|
2. The nozzle is not clean or broken |
||
|
3. Insufficient cutting air pressure |
||
|
4.镜The lens is dirty or damaged |
KNOPPO LASER has a solution for any laser cutting requirement you may have. Sales – Installations – Service – Support – Training – your trusted laser partner .